Ces radiol. 2008, 62(3):302-308
Evaluation of efficiency of chemotherapy in patients with osteosarcoma using CT perfusionReview article
- 1 Radiodiagnostická klinika 1. LF UK FN Na Bulovce, Praha
- 2 Ortopedická klinika IPVZ a 1. LF UK FN Na Bulovce, Praha
It has been proven, that CT Body Perfusion, which has proven to be one of the method to use for the impact of the therapy in time, can monitor hypervascular tumors like osteosarcoma. Observation is useful especially with the tumors growing in the soft tissues around the bone. CT Body Perfusion shows the started new direction in monitoring of effect of oncology treatment. Resulting perfusion maps can be evaluated qualitatively or even more precise quantitatively.
Keywords: CT body perfusion, CT perfusion tumor, dynamic study, osteosarcoma
Grants and funding:
Práce byla podpořena výzkumným záměrem MZČR č. MZ 0002384101.
Accepted: August 14, 2008; Published: September 1, 2008 Show citation
References
- Dungl P, et al. Ortopedie. Praha: Avicenum - Grada Publishing 2005.
- Povýšil C, Šteiner I, et al. Speciální Patologie. Praha: Galén 2007.
- Ferda J, Novák M, Kreutzberg B. Výpočetní Tomografie. Praha: Galén 2002.
- Ferda J. CT Angiografie. Praha: Galén 2004.
- Fichte H. Functional CT. Munich: Siemens AG 2005.
- Hakimé A, Peddi H, et al. CT perfusion for Determination of Pharmacologically Mediated Blood Flow Changes in an Animal Tumor Model. Radiology 2007; 243: 712-719.
Go to original source...
Go to PubMed...
- Bellomi M, Petralia G, Sonzogni A, et al. CT Perfusion for the Monitoring of Neoadjuvant Chemotherapy and Radiation Therapy in rectal Carcinoma: Initial Experience. Radiology 2007; 244: 486-493.
Go to original source...
Go to PubMed...
- Makari Y, Yasuda T, Doki Y, Miyata H. Correlation Between Tumor Blood Flow Assessed by Perfusion CT and Effect of Neoadjuvant Therapy in Advanced Esophageal Cancers. Journal of Surgical Oncology 2007; 96: 220-229.
Go to original source...
Go to PubMed...
- Quan-Sing N, Goh V, Fichte H, et al. Lung Cancer Perfusion at Multi-detector Row CT: Reproducibility of the Whole Tumor Quantitative Measurements. Radiology 2006; 239: 547-553.
Go to original source...
Go to PubMed...
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.