Ces radiol. 2013, 67(1):81-86

Radiation dose reduction to the eye lens in cerebral MDCT using iterative reconstruction algorithm IRIS - first resultsOriginal article

Jiří Jandura, Jan Žižka, Tomáš Kvasnička, Jan Grepl, Ludovít Klzo
Radiologická klinika FN a LF UK, Hradec Králové

Aim: To compare effective and organ radiation dose to the eye lens in multidetector CT (MDCT) examinations of the brain, utilising either iterative reconstruction in image space (IRIS) or filtered back projection (FBP) algorithm.

Method: Of 80 non-acute brain MDCT examinations, 40 were performed with IRIS reconstruction algorithm and other 40 with FBP algorithm. All examinations were performed on MDCT system SOMATOM Definition AS+ (Siemens Healthcare, Forchheim, Germany).
Calculation of the effective dose was done by ImPACT software (Impact, London) using CT dose index (CTDIvol) and dose length product (DLP) values. Organ dose to the eye lens was calculated from mAs value applied to the slices containing the lens. Diagnostic image quality of reconstructed data was evaluated by two experienced radiologists in a blinded fashion.

Results: For IRIS, the average effective dose to the eye lens was 1.04 ± 0.21 mSv and for FBP 1.53 ± 0.29 mSv, with a reduction of approximately of 32%. The average organ dose for IRIS was 26.9 ± 1.9 mGy and 40.2 ± 3.2 mGy for FBP, with a dose reduction of 33.1%. A comparison of image quality showed no statistically significant difference (p = 0.21). Quantitative analysis of image noise revealed slightly increased noise levels in the IRIS group, the difference was statistically significant (p < 0.01).

Conclusion: IRIS reconstruction algorithm in cerebral MDCT examinations can reduce the effective and eye lens organ dose approximately by one third, without significant deterioration of image quality compared to FBP reconstruction algorithm FBP.

Keywords: multidetector computed tomography, image processing, eye lens, cataract

Accepted: November 17, 2012; Published: March 1, 2013  Show citation

ACS AIP APA ASA Harvard Chicago Chicago Notes IEEE ISO690 MLA NLM Turabian Vancouver
Jandura J, Žižka J, Kvasnička T, Grepl J, Klzo L. Radiation dose reduction to the eye lens in cerebral MDCT using iterative reconstruction algorithm IRIS - first results. Ces radiol. 2013;67(1):81-86.
Download citation

References

  1. Mettler FA Jr, Bhargavan M, Faulkner K, et al. Radiologic and nuclear medicine studies in the United States and worldwide: frequency, radiation dose, and comparison with other radiation sources 1950-2007. Radiology 2009; 253(2): 520-531. Go to original source... Go to PubMed...
  2. Kalra MK, Maher MM, Toth TL, et al. Strategies for CT radiation dose optimization. Radiology 2004; 230(3): 619-628. Go to original source... Go to PubMed...
  3. Rockmore AJ, Macovski A. A maximum likelihood approach to emission image reconstruction from projections. IEEE Trans Nucl Sci 1976; 23(4): 1428-1432. Go to original source...
  4. Leipsic J, Labounty T, Heilbron B, et al. Estimated radiation dose reduction using adaptive statistical iterative reconstruction in coronary CT angiography: the ERASIR study. Am J Roentgenol 2010; 195(3): 655-660. Go to original source... Go to PubMed...
  5. Pontana F, Pagniez J, Flohr T, et al. Chest computed tomography using iterative reconstruction vs filtered back projection (Part 1): evaluation of image noise reduction in 32 patients. Eur Radiol 2011; 21(3): 636-643. Go to original source... Go to PubMed...
  6. Schauer DA, Linton OW. NCRP report no. 160, ionizing radiation exposure of the population of the United States, medical exposure: are we doing less with more, and is there a role for health physicists? Health Phys 2009; 97(1): 1-5. Go to original source... Go to PubMed...
  7. Larson DB, Johnson LW, Schnell BM, Salisbury SR, Forman HP. National trends in CT use in the emergency department: 1995-2007. Radiology 2011; 258(1): 164-173.
  8. United Nations Scientific Committee on the Effects of Atomic Radiation. Sources and effects of ionizing radiation. Medical radiation exposures, annex A. United Nations, New York. http://www.unscear.org/docs/reports/2008/09-86753_Report_2008_Annex_A.pdf
  9. Prakash P, Kalra MK, Ackman JB, et al. Diffuse lung disease: CT of the chest with adaptive statistical iterative reconstruction technique. Radiology 2010; 256(1): 261-269. Go to original source... Go to PubMed...
  10. Leipsic J, LaBounty TM, Heilbron B, et al. Adaptive statistical iterative reconstruction: assessment of image noise and image quality in coronary CT angiography. AJR Am J Roentgenol 2010; 195(3): 649-654. Go to original source... Go to PubMed...
  11. Sagara Y, Hara AK, Pavlicek W, Silva AC, Paden RG, Wu Q. Abdominal CT: comparison of lowdose CT with adaptive statistical iterative reconstruction and routine-dose CT with filtered back projection in 53 patients. AJR Am J Roentgenol 2010; 195(3): 713-719. Go to original source... Go to PubMed...
  12. Flicek KT, Hara AK, Silva AC, et al. Reducing the radiation dose for CT colonography using adaptive statistical iterative reconstruction: a pilot study. AJR Am J Roentgenol 2010; 195(1): 126-131. Go to original source... Go to PubMed...
  13. Mitsumori LM, Shuman WP, Busey JM, Kolokythas O, Koprowicz KM. Adaptive statistical iterative reconstruction versus filtered back projection in the same patient: 64 channel liver CT image quality and patient radiation dose. Eur Radiol 2012; 22(1): 138-143. Go to original source... Go to PubMed...
  14. Leipsic J, Nguyen G, Brown J, Sin D, Mayo JR. A prospective evaluation of dose reduction and image quality in chest CT using adaptive statistical iterative reconstruction. AJR Am J Roentgenol 2010; 195(5): 1095-1099. Go to original source... Go to PubMed...
  15. Singh S, Kalra MK, Gilman MD, et al. Adaptive statistical iterative reconstruction technique for radiation dose reduction in chest CT: a pilot study. Radiology 2011; 259(2) 565-573. Go to original source... Go to PubMed...
  16. Cornfeld D, Israel G, Detroy E, Bokhari J, Mojibian H. Impact of adaptive statistical iterative reconstruction (ASIR) on radiation dose and image quality in aortic dissection studies: a qualitative and quantitative analysis. AJR Am J Roentgenol 2011; 196(3): W336-W340. Go to original source... Go to PubMed...
  17. Kilic K, Erbas G, Guryildirim M, et al. Lowering the dose in head CT using adaptive statistical iterative reconstruction. AJNR Am J Neuroradiol 2011; 32(9): 1578-1582. Go to original source... Go to PubMed...
  18. Rapalino O, Kamalian S, Kamalian S, et al. Cranial CT with adaptive statistical iterative reconstruction: improved image quality with concomitant radiation dose reduction. AJNR Am J Neuroradiol 2012; 33(4): 609-615. Go to original source... Go to PubMed...
  19. Korn A, Fenchel M, Bender B, et al. Iterative reconstruction in head CT: image quality of routine and low-dose protocols in comparison with standard filtered back-projection. AJNR Am J Neuroradiol 2012; 33(2): 218-224. Go to original source... Go to PubMed...
  20. International Commission on Radiological Protection. Statement on tissue reactions. International Commission on Radiological Protection, ref 4825-3093-1464, Seoul. https://rpop.iaea.org/RPOP/RPoP/Content/Documents/Whitepapers/ICRP-statements-tissue-reactions.pdf.

This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.