Ces radiol. 2016, 70(1):9-15 | DOI: 10.55095/CesRadiol2016/002
3T magnetic resonance diffusion imaging of tissues by means of RESOLVE (REadout Segmentation Of Long Variable Echo-trains) techniqueReview article
- Klinika zobrazovacích metod LF UK a FN, Plzeň
Diffusion-weighted tissue imaging is very important part of magnetic resonance examination protocols. There is significant decrease of its quality in 3T compared to 1,5T machines if conventional techniques of data collections are used, and new methods are needed to be applied. RESOLVE (REadout Segmentation Of Long Variable Echo-trains) technique represents an option reducing geometric distortions and providing higher spatial resolution, however, with prolonged examination duration.
Keywords: magnetic resonance, diffusion weighted imaging, echo-planar imaging, RESOLVE
Grants and funding:
Podpořeno projektem Ministerstva zdravotnictví ČR Koncepční rozvoj výzkumné instituce 00669806 - FN Plzeň a Programem rozvoje vědních oborů Karlovy Univerzity (projekt P36).
Accepted: February 15, 2016; Published: March 1, 2016 Show citation
ACS | AIP | APA | ASA | Harvard | Chicago | Chicago Notes | IEEE | ISO690 | MLA | NLM | Turabian | Vancouver |
References
- Schaefer PW, Grant PE, Gonzalez RG. Diffusion-weighted MR imaging of the brain. Radiology 2000; 217(2): 331-345.
Go to original source...
Go to PubMed...
- Koh DM, Collins DJ. Diffusion-weighted MRI in the body: applications and challenges in oncology. AJR Am J Roentgenol 2007; 188(6): 1622-1635.
Go to original source...
Go to PubMed...
- Springer E, Dymerska B, Cardoso PL, Robinson SD, Weisstanner C, Wiest R, Schmitt B, Trattnig S. Comparison of Routine Brain Imaging at 3 T and 7 T. Invest Radiol 2016;; Feb 8 [Epub ahead of print].
Go to original source...
Go to PubMed...
- Lavdas I, Miquel ME, McRobbie DW, Aboagye EO. Comparison between diffusion-weighted MRI (DW-MRI) at 1.5 and 3 tesla: a phantom study. J Magn Reson Imaging 2014; 40(3): 682-690.
Go to original source...
Go to PubMed...
- Stejskal EO. Use of spin echoes in a pulsed magnetic-field gradient to study naisotropic, restricted diffusion and flow. J Chem Phys 1965; 43: 3597.
Go to original source...
- Poustchi-Amin M, Mirowitz SA, Brown JJ, McKinstry RC, Li T. Principles and applications of echo-planar imaging: a review for the general radiologist. Radiographics 2001; 21(3): 767-779.
Go to original source...
Go to PubMed...
- Graessner J. Bandwith in MRI? Siemens Healthcare, Hamburg, Germany (www.healthcare.siemens.com)
- Holdsworth SJ, Skare S, Newbould RD, Guzmann R, Blevins NH, Bammer R. Readout-segmented EPI for rapid high resolution diffusion imaging at 3 T. Eur J Radiol 2008; 65(1): 36-46 [Epub 2007, Nov 5].
Go to original source...
Go to PubMed...
- Frost R, Porter DA, Miller KL, Jezzard P. Implementation and assessment of diffusion-weighted partial Fourier readout-segmented echo-planar imaging. Magn Reson Med 2012; 68(2): 441-451.
Go to original source...
Go to PubMed...
- Porter DA, Heidemann RM. High resolution diffusion-weighted imaging usingreadout-segmented echo-planar imaging, parallel imaging and a two-dimensional navigator-based reacquisition. Magn Reson Med 2009; 62(2): 468-475.
Go to original source...
Go to PubMed...
- Porter DA. 2D-navigator-based re-acquisition for motion artefact suppression in multi-shot, diffusion-weighted imaging. In: Proceedings of the 14th Annual Meeting of ISMRM, Seattle, Washington, USA 2006 (abstract 1047).
- Miller KL, Pauly JM. Nonlinear phase correction for navigated diffusion imaging. Magn Reson Med 2003; 50(2): 343-353.
Go to original source...
Go to PubMed...
- Nguyen Q, Clemence M, Ordidge RJ. The use of intelligent re-acquisition to reduce scan time in MRI degraded by motion. In: Proceedings of the 6th Annual Meeting of ISMRM, Sydney, Australia 1998 (abstrakt 134).
- Heidemann RM, Porter DA, Anwander A, Feiweier T, Heberlein K, Knösche TR, Turner R. Diffusion imaging in humans at 7T using readout-segmented EPI and GRAPPA. Magn Reson Med 2010; 64(1): 9-14.
Go to original source...
Go to PubMed...
- Frost R, Jezzard P, Douaud G, Clare S, Porter DA, Miller KL. Scan time reduction for readout-segmented EPI using simultaneous multislice acceleration: Diffusion-weighted imaging at 3 and 7 Tesla. Magn Reson Med 2014; 74: 136-149.
Go to original source...
Go to PubMed...
- Kida I, Ueguchi T, Matsuoka Y, Zhou K, Stemmer A, Porter D. Comparison of Diffusion-Weighted Imaging in the Human Brain Using Readout-Segmented EPI and PROPELLER Turbo Spin Echo With Single-Shot EPI at 7 T MRI. Invest Radiol 2016; Jan 20 [Epub ahead of print].
Go to original source...
Go to PubMed...
- Yeom KW, Holdsworth SJ, Van AT, Iv M, Skare S, Lober RM, Bammer R. Comparison of readout-segmented echo-planar imaging (EPI) and single-shot EPI in clinical application of diffusion-weighted imaging of the pediatric brain. AJR Am J Roentgenol 2013; 200(5): W437-443.
Go to original source...
Go to PubMed...
- Bogner W, Pinker-Domenig K, Bickel H, Chmelik M, Weber M, Helbich TH, Trattnig S, Gruber S. Readout-segmented echo-planar imaging improves the diagnostic performance of diffusion-weighted MR breast examinations at 3.0 T. Radiology 2012; 263(1): 64-76.
Go to original source...
Go to PubMed...
This is an open access article distributed under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0), which permits use, distribution, and reproduction in any medium, provided the original publication is properly cited. No use, distribution or reproduction is permitted which does not comply with these terms.